日韩一区二区三区精品,欧美疯狂xxxxbbbb牲交,热99re久久免费视精品频,人妻互换 综合,欧美激情肉欲高潮视频

你現(xiàn)在的位置>>白皮書 >> 電源管理 >> A PRIMER ON DRIVING INCANDESCENT LAMPS

A PRIMER ON DRIVING INCANDESCENT LAMPS


內(nèi)容簡介

Tungsten-filament incandescent lamps exhibit a very-high
positive temperature coefficient of resistance with the cold filament
resistance being approximately 10% of the hot filament resistance.
When an incandescent lamp is initially turned on, the cold filament
is at minimum resistance and will normally allow a 10x to 12x peak
current. Within 3 to 5 ms the current falls to approximately 2x the
hot current. This high lamp turn-on current (commonly called
“in-rush” current), can contribute to poor lamp reliability and can
destroy semiconductor lamp drivers. Even if the active part of the
driver output could survive the short-duration peak current, the
internal bonding wires can “fuse” open. High-current drivers or
paralleled drivers, rated to handle the peak inrush current, may
prove cost prohibitive.


下載說明

發(fā)布公司:Allegro
更新時(shí)間:2009-12-30
文件大小:72.33 Kb
下載次數(shù): 132